Artificial intelligence (AI) policy: ASHRAE prohibits the entry of content from any ASHRAE publication or related ASHRAE intellectual property (IP) into any AI tool, including but not limited to ChatGPT. Additionally, creating derivative works of ASHRAE IP using AI is also prohibited without express written permission from ASHRAE.

Close
logoShaping Tomorrow's Built Environment Today

V in HVAC – Energy Efficient HVAC Systems Design

Share This

V in HVAC – Energy Efficient HVAC Systems Design

  • 15 Oct 2024
  • 15 October 2024
    Virtual | Part I | 12:00 pm – 3:00 pm EDT

    16 October 2024
    Virtual | Part II | 8:00 am – 12:00 pm EDT

REGISTER NOW

Course Description

Fee:

$573 ($458 ASHRAE Member)

Includes course materials, Certificate of Attendance, and course recording.


Course Description

This seminar covers the essential aspects of ASHRAE Standard 62.1-2022 and equips students with the knowledge and skills to design more efficient ventilation systems. The seminar starts by focusing on the basic requirements of ASHRAE Standard 62.1-2022, covering its scope, application, and multiple compliance paths, including the ventilation rate procedure, indoor air quality procedure, and natural ventilation procedure. Topics include crucial aspects such as minimum requirements for cleaning outdoor air, designing HVAC systems, determining ventilation rate quantities, and effective commissioning, as well as proper operations and maintenance practices. The seminar explores constant volume and variable air volume (VAV) recirculating systems for both single zone and multiple zone spaces. Fundamental insights into designing Dedicated Outdoor Air Systems (DOAS) ventilation and comparing energy usage among various ventilation system types, guiding you in making informed and environmentally responsible choices are covered.  This seminar is designed for attendees to gain a comprehensive understanding of ASHRAE Standard 62.1-2022 and the principles of ventilation design to create ventilation systems that meet the highest standards of efficiency and compliance with ASHRAE standards.

Learning Objectives:

  • Explain the three major types of contaminants in the air and give an example of a source for each.
  • List the five major requirement sections of ASHRAE Standard 62.1-2022
  • Understand that different approaches to HVAC design using the Ventilation Rate Procedure result in different quantities of outside air at the outside air intake.
  • Contrast the Ventilation Rate Procedure, the Indoor Air Quality Procedure, and the Natural Ventilation Procedure.
  • Explain the adjustment factors for any system designed with the VRP that converts the breathing zone ventilation rates to outdoor air intake ventilation rate; Know two techniques for improving system ventilation efficiency.

Recommended Publications:

ANSI/ASHRAE Standard 62.1-2022, Ventilation for Acceptable Indoor Air Quality

Interested in prepping for the High-Performance Building Design Professional (HBDP) certification exam? See a complete list of HBDP exam task content areas in this course. 


Course Instructors:

Hoy Bohanon, P.E., BEAP, Member ASHRAE, LEED® AP

Marwa Zaatari, Ph.D., Associate Member


Cancellation Policy

Course registration fees will be refunded in full if ASHRAE Customer Service receives cancellation at 800-527-4723 or edu@ashrae.org before 12:00 noon, seven working days before the course date. Cancellations received between three and seven working days before the course date are subject to a $50 cancellation fee. Registrants who do not attend a course or cancel less than three working days before the course date are liable for the entire course registration fee. Registration fees can be transferred by contacting ASHRAE Customer Service at 800-527-4723 or edu@ashrae.org.

Close