Artificial intelligence (AI) policy: ASHRAE prohibits the entry of content from any ASHRAE publication or related ASHRAE intellectual property (IP) into any AI tool, including but not limited to ChatGPT. Additionally, creating derivative works of ASHRAE IP using AI is also prohibited without express written permission from ASHRAE. For the full AI policy, click here. 

Close
logoShaping Tomorrow’s Global Built Environment Today

Interpretations For Standard 135-2012

NOTE: All documents linked from this page are in pdf_icon.png PDF-format.

pdf_icon.png Interpretation 135-2012-1 – May 9, 2013 (Refers to the requirements presented in ANSI/ASHRAE 135-2012, Clause 12.25.14, relating to recording time-change events in trendlog logbuffer.)

pdf_icon.png Interpretation 135-2012-2 – June 22, 2013 (Refers to ANSI/ASHRAE Standard 135-2012, Clause 19, regarding the Command Prioritization.)

pdf_icon.png Interpretation 135-2012-3 – June 22, 2013 (Refers to the requirements presented in ANSI/ASHRAE 135-2012, Clause K.5.23, relating to BBIB – Device Management-Object Creation and Deletion-A (DM-OCD-A).)

pdf_icon.png Interpretation 135-2012-4 – June 22, 2013 (Refers to the requirements presented in ANSI/ASHRAE 135-2012, Clause 12.25.10, relating to details on client behavior for retrieving external property values by COV or polling.)

pdf_icon.png Interpretation 135-2012-5 – June 22, 2013 (Refers to ANSI/ASHRAE Standard 135-2012, Clauses 12.4.9, 12.8.9 and 12.20.9, regarding the Out_Of_Service property.)

pdf_icon.png Interpretation 135-2012-6 – November 6, 2013 (Refers to the requirements presented in ANSI/ASHRAE 135-2012, Clause 12.9.6, relating to the behavior of the Present_Value in a Calendar when the Date_List contains a specific day-of-week, and any of the special third octet values.)

pdf_icon.png Interpretation 135-2012-7 – November 6, 2013 (Refers to the requirements presented in ANSI/ASHRAE 135-2012, Clause 15.10.1.3 and 15.10.2, relating to error handling of WritePropertyMultiple Service.)

pdf_icon.png Interpretation 135-2012-8 – November 6, 2013 (Refers to the requirements presented in ANSI/ASHRAE 135-2012, Clauses 12.18.10 and 13.4.5, relating to the correct value of reliability when OutOfService.)

pdf_icon.png Interpretation 135-2012-9 – November 6, 2013 (Refers to the requirements presented in ANSI/ASHRAE 135-2012, Clause 12, relating to the execution of alarming related messages containing timestamps with wildcards.)

pdf_icon.png Interpretation 135-2012-10 – January 18, 2014 (Refers to the requirements presented in ANSI/ASHRAE 135-2012, Clause 15.8.2, relating to ReadRange executed with a Range parameter of 'byTime'.)

pdf_icon.png Interpretation 135-2012-11 – January 18, 2014 (Refers to the requirements presented in ANSI/ASHRAE Standard 135-2012, Clause 12.25.14, regarding all logging objects (TL, TLM, EL).)

pdf_icon.png Interpretation 135-2012-12 – April 9, 2014 (Refers to the requirements presented in ANSI/ASHRAE Standard 135-2012, Clause 5, regarding all Property MaxSegmentsAccepted, Client State Machine.)

pdf_icon.png Interpretation 135-2012-13 – January 24, 2015 (Refers to the requirements presented in ANSI/ASHRAE Standard 135-2012, Clause 19.1.3.3, regarding file objects using record-access.)

pdf_icon.png Interpretation 135-2012-14 – January 24, 2015 (Refers to the requirements presented in ANSI/ASHRAE Standard 135-2012, Clause 19.1.3.3, regarding restoring the configuration files.)

pdf_icon.png Interpretation 135-2012-15 – January 24, 2015 (Refers to the requirements presented in ANSI/ASHRAE Standard 135-2012, Clause 15.8, regarding ReadRange Service, by position with negative count.)

pdf_icon.png Interpretation 135-2012-16 – April 30, 2015 (Refers to the requirements presented in ANSI/ASHRAE Standard 135-2012, Clause 13.7, regarding UnconfirmedCOVNotification Service, K1-11 BIBB DS-COV-A.)

pdf_icon.png Interpretation 135-2012-17 – April 30, 2015 (Refers to the requirements presented in ANSI/ASHRAE 135-2012, Clauses 12.25.14, 12.30.19, and 21 (BACnetLogData and BACnetLogRecord) relating to trending.)

pdf_icon.png Interpretation 135-2012-18 – November 4, 2015 (Refers to the requirements presented in ANSI/ASHRAE Standard 135-2012, Clause 13.14, regarding SubscribeCOV service with indefinite lifetime.)

pdf_icon.png Interpretation 135-2012-19 – November 4, 2015 (Refers to the requirements presented in ANSI/ASHRAE Standard 135-2012, Clauses 12.12.8, 15.3.1.3.1, 15.9.1.3.1 and 15.10.1.3.1, regarding error returned to a CreateObject service.)

pdf_icon.png Interpretation 135-2012-20 – April 19, 2016 (Refers to the requirements presented in ANSI/ASHRAE Standard 135-2012, Clause 12.11.39, regarding Optionality of COV_Increment in Active_COV_Subscriptions.)