Artificial intelligence (AI) policy: ASHRAE prohibits the entry of content from any ASHRAE publication or related ASHRAE intellectual property (IP) into any AI tool, including but not limited to ChatGPT. Additionally, creating derivative works of ASHRAE IP using AI is also prohibited without express written permission from ASHRAE. For the full AI policy, click here. 

Close
logoShaping Tomorrow’s Global Built Environment Today

Interpretations for Standard 62.1-2004

Share This

NOTE: All documents linked from this page are in pdf_icon.png PDF-format.

 Interpretation 62.1-2004-01 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Section 6.2.6.2 Short-Term Conditions, specifically the interruption of ventilation air.)

 Interpretation 62.1-2004-2 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1 Minimum Ventilation Rates in Breathing Zone, specifically for the Occupancy Category: Swimming (pool and deck).)

 Interpretation 62.1-2004-3 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1, Minimum Ventilation Rates in Breathing Zone, relating to Swimming (pool and deck))

 Interpretation 62.1-2004-4 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1, Minimum Ventilation Rates in Breathing Zone, relating to General: Corridors)

 Interpretation 62.1-2004-5 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Section 6.3.1.1 Contaminant Sources)

 Interpretation 62.1-2004-6 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Sections 6.2.2 Zone Calculations, 6.2.6.2 Short-Term Conditions, and 6.2.7 Dynamic Reset.)

 Interpretation 62.1-2004-7 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1, General Note 7, and Table E-3 relating to vehicles.)

 Interpretation 62.1-2004-8 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1, Minimum Ventilation Rates in Breathing Zone, relating to an Office Building.)

 Interpretation 62.1-2004-9 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Section 6.2.2 Zone Calculations and Table 6-1 Minimum Ventilation Rates in Breathing Zone, relating to Retail spaces.)

 Interpretation 62.1-2004-10 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1 Minimum Ventilation Rates in Breathing Zone, relating to indoor contaminant levels.)

 Interpretation 62.1-2004-11 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1 and Section 6.2.9, relating to smoking areas and ETS.)

 Interpretation 62.1-2004-12 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Section 6.3 Indoor Air Quality Procedure, relating to ETS.)

 Interpretation 62.1-2004-13 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Section 6.2 Ventilation Rate Procedures, specifically Sections 6.2.2.1, 6.2.5.3, and 6.2.6.2 relating to the calculation of system average population.)

 Interpretation 62.1-2004-14 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Table 6-1 Minimum Ventilation Rates in Breathings Zone – dormitories, patient rooms and pet shops, and Sections 6.2 and 8.1.3 relating to buildings alterations or change-of-use dealing with pets.)

 Interpretation 62.1-2004-15 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Section 6.2 Ventilation Rate Procedure, specifically Section 6.2.5.2 and Appendix A and the VRP Excel Spreadsheet.)

 Interpretation 62.1-2004-16 (Refers to the requirements in ANSI/ASHRAE Standard 62.1-2004, Section 4.1 and Table 4-1, regarding regional air quality and NAAQS for pollutants outside of the United States.)

Interpretation 62.1-2004-17 - January 25, 2009 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2004, Section 5.1.1, and Appendix E, Table E-2, regarding the location of operable windows for natural ventilation.) 

Interpretation 62.1-2004-18 - January 25, 2009 (Refers to ANSI/ASHRAE Standard 62.1-2004, Sections 3 and 5.1.1 related to the distance of an operable wall regarding occupiable space.)

Interpretation 62.1-2004-19 - June 20, 2009 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1 -2004 Section 6.2.2.1 and the relevance of using local exhaust fans in high-rise residential projects to provide mechanical ventilation.)

 Interpretation 62.1-2004-20 January 23, 2010 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1 -2004, Section 5.1, specifically the exception to 5.1, regarding the definition of an authority having jurisdiction.)

Interpretation 62.1-2004-21 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1 -2004, Section 3 and Table 5.1, regarding separation distance.)