Artificial intelligence (AI) policy: ASHRAE prohibits the entry of content from any ASHRAE publication or related ASHRAE intellectual property (IP) into any AI tool, including but not limited to ChatGPT. Additionally, creating derivative works of ASHRAE IP using AI is also prohibited without express written permission from ASHRAE. For the full AI policy, click here. 

Close
logoShaping Tomorrow’s Global Built Environment Today

Interpretations for Standard 62.1-2007

Share This

NOTE: All documents linked from this page are in pdf_icon.png PDF-format.

 Interpretation 62.1-2007-1 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Table 5-1 “Air Intake Separation Distance”, Appendix F “Separation of Exhaust Outlets and Outdoor Air Intakes”, and Table 6-4 “Minimum Exhaust Rates” regarding separation distances between Air Class 2 and 3 Exhaust and an Outdoor Air intake.)

 Interpretation 62.1-2007-2 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Section 6.2.2 and Table 6-2, regarding zone air distribution effectiveness (EZ) values.)

 Interpretation 62.1-2007-3 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Section 6.2.6.2 Short-Term Conditions, specifically the interruption of ventilation air.)

 Interpretation 62.1-2007-4 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Table 6-1 Minimum Ventilation Rates in Breathing Zone, specifically for the Occupancy Category: Swimming (pool and deck).)

 Interpretation 62.1-2007-5 (Refers to ASHRAE Standard 62.1-2007, Table 6-1, Minimum Ventilation Rates in Breathing Zone.)

 Interpretation 62.1-2007-6 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Table 6-1, Minimum Ventilation Rates in Breathing Zone, relating to General: Corridors.)

 Interpretation 62.1-2007-7 (Refers to ANSI/ASHRAE 62.1-2007 Sections 6.2.2 Zone Calculations, 6.2.6.2 Short-Term Conditions, and 6.2.7 Dynamic Reset.)

 Interpretation 62.1-2007-8 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Table 6-1, Minimum Ventilation Rates in Breathing Zone- Commercial Facilities.)

 Interpretation 62.1-2007-9 (Refers to the Ventilation Rate Procedure presented in ANSI/ASHRAE Standard 62.1-2007, particularly Section 6.2.2, Zone Calculations, and Table 6-1, Outdoor Air Requirements for Ventilation.)

 Interpretation 62.1-2007-10 (Refers to Table 6-1 of ANSI/ASHRAE Standard 62.1-2007 dealing with Minimum Ventilation Rates in Breathing Zone.)

 Interpretation 62.1-2007-11 (Refers to changes to the Standard as a result of ANSI/ASHRAE Addendum o to ANSI/ASHRAE Standard 62-2001 that are now incorporated in ANSI/ASHRAE Standard 62.1-2007. The changes include removal of the reference to smoking spaces in Table 6-1 of outdoor air requirements per general note 2 and addition of a requirement for additional ventilation and/or air cleaning in spaces where smoking is permitted and prohibits the recirculation or transfer of air from smoking to no-smoking areas per Section 6.2.9.)

 Interpretation 62.1-2007-12 (Refers to changes to the Standard as a result of Addendum “h” to ANSI/ASHRAE Standard 62-2001 that modified the Indoor Air Quality (IAQ) Procedure and are now incorporated as Section 6.3 of ANSI/ASHRAE Standard 62.1-2007.)

 Interpretation 62.1-2007-13 (Refers to Addendum “n” to ANSI/ASHRAE Standard 62-2001 that incorporates a new Ventilation Rate Procedure in Section 6.2, specifically related to the calculation of system average population in Sections 6.2.2.1, 6.2.5.3 and 6.2.6.2.)

  Interpretation 62.1-2007-14 (Refers to Table 6-1, Minimum Ventilation Rates in Breathing Zone, application of rates for dormitories, patient rooms, and pet shops, Section 6.2, and Section 8.1.3 Building Alterations or Change-of-Use dealing with pets.)

 Interpretation 62.1-2007-15 (Refers to Addendum “n” to ANSI/ASHRAE Standard 62-2001 that incorporates a new Ventilation Rate Procedure in Section 6.2 of ANSI/ASHRAE Standard 62.1-2007, specifically Section 6.2.5.2 and Appendix A and the VRP Excel Spreadsheet.)

 Interpretation 62.1-2007-16 - January 23, 2010 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Sections 2.1, 3, 6 and Table 6-1, regarding ventilation requirements for spaces which are not occupiable.)

 Interpretation 62.1-2007-17 - January 23, 2010 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Sections 3, 6 and Table 6-1, regarding minimum ventilation rates in breathing zone for spaces which are not occupiable.)

 Interpretation 62.1-2007-18 - January 23, 2010 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Sections 5.4 and 6.2.8, and Table 6-4, regarding exhaust ventilation and fan system operation.)

Interpretation 62.1-2007-19 - June 27, 2010 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Section 6.2 and Table 6-1, regarding ventilation requirements for refrigerated warehouse space.)

 Interpretation 62.1-2007-20 – January 29, 2011 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Section 6.2 and Table 6-1, regarding ventilation requirements for Hotels, Motels, Resorts, and Dormitories.)

 Interpretation 62.1-2007-21 – January 29, 2011 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Sections 6.2.6 and 6.2.7, regarding ventilation during heat pump defrost cycle.)

  Interpretation 62.1-2007-22 – June 26, 2011 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007 Section 6.2.2.1 and the relevance of using local exhaust fans in high-rise residential projects to provide mechanical ventilation.)

 Interpretation 62.1-2007-23 – January 21, 2012 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1 -2007, Sections 3, 6.1.2, 6.3 and 6.2.6, specifically Table 6-4, regarding IAQ Procedure (air cleaning) of toilet exhaust)

 Interpretation 62.1-2007-24 – January 21, 2012 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Section 6.3 Indoor Air Quality Procedure, and Table 6-2, relating to Zone Air Distribution Effectiveness (Ez).)

 Interpretation 62.1-2007-25 – January 25, 2013 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Section 6.4 and Table 6-4, regarding design documentation and exhaust rates for copy/printing rooms.)

 Interpretation 62.1-2007-26 – January 24, 2016 (Refers to the requirements presented in ANSI/ASHRAE Standard 62.1-2007, Section 6.2 and Tables 6-1, 6-2 and 6-4, regarding ventilation requirements for office buildings and their garage and rest rooms.)

Close